Gas Generator CG132B-16

The Cat CG132B family of gas engines are perfectly tailored to the challenges of the power plant in an age of global value chains.
Highly efficient with low operating and installation costs and lubricant consumption, the Cat CG132B gas generator set is available with outputs from 400kW to 1000kW and comes with the Total Plant and Energy Management (TPEM) system.

Key Specs

  • Continuous Rating 1000 ekW @1.0pf
  • Fuel Type Natural Gas, Hydrogen Blend (up to 25%)
  • Maximum Electrical Efficiency 41.50%

Benefits

Up to 25%

hydrogen blended fuel option

Enables operation of up to 25% hydrogen blend (by volume) with pipeline natural gas fuel.

Digital Plant Control

Total Plant and Energy Management System (TPEM) gives you comprehensive and flexible digital control of your generator set�s efficiency and performance helping to reduce planning and installation costs.

Robust

Improved oil management with optimized cylinder and turbo chargers set new standards in terms of durability and reliability.

Generator Set Specifications

Continuous Rating 1000 ekW @1.0pf
Fuel Type Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency 41.50%
Frequency 50 Hz
RPM 1500 rpm
Natural Gas Rating 1000

Engine Specifications

Engine Model CG132B
Displacement 2135.8in³
Aspiration TA
Bore 5.2in
Stroke 6.3in

Generator Set Dimensions

Length 165in
Width 70in
Height 85in
Dry Weight - Genset 17791lb

Lower Operating Costs

  • Optimized engine components mean the CG132 uses up to 50% less lubricating oil than competing generator sets, which means more money stays in your company's pockets

Smaller footprint

  • The CG132 uses nearly 50% less space than similar system
  • Less space means lower installation costs

Cat Total Electronic Management System

  • Temperature and pressure monitoring for each cylinder
  • Anti-knock control allow for maximum power output and the best possible fuel utilization, even if gas composition changes

Flexible Fuel Usage

  • Our gas-mixer technology and Total Electronic Management System let you use a wide variety of gases, including problematic gases like digester, landfill and sewage gases

Standard Equipment

  • Air Inlet
    • One-element single-stage air cleaner with enclosure and sevice indicator
    • Turbocharger with a water-cooled bearing case for all cylinder
  • Control Panels
    • TPEM (Total Plant & Energy Management System)
  • Cooling
    • Flange connections for JW inlet and outlet
    • Electrical jacket water and aftercooler coolant pump
    • Jacket water and SCAC thermostats
    • flange connections for JW inlet and outlet
    • Cat flanges on SCAC circuit
    • ANSI/DN customer flange connections for JW inlet and outlet
  • Exhaust
    • Exhaust waste gate for the CG132B-16
    • Closed crankcase ventilation system
    • PEARL/Low resistence exhaust system
  • Fuel System
    • Pre-chamber spark plugs
    • Independently controlled cylinder monitoring and ignition system
    • Electronic fuel metering valve
  • Generator
    • Anti-condensation space heater
    • Reactive droop
    • 3-phase sensing and KVAR/PF control
    • Busbar connections
    • grid code generator
    • closed-coupled generator result in no torque transmission to the base frame
    • Reactive droop
    • Winding temperature detectors
  • Starting/charging
    • 24V starting motors
    • Battery disconnect switch
  • General
    • Crankshaft vibration damper and guard

Optional Equipment

  • Air Inlet
    • Air cleaner with precleaner
    • Mounting stand
  • Cooling
    • CHP skid
  • Grid Code Compliance
    • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands