D175 GC Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Key Specs

  • Standby Rating 175 ekW
  • Frequency 60 Hz
  • Emissions/Fuel Strategy U.S. EPA Tier 3 Certified

Benefits

Saves up to 16%

Installed Space

Requires less space for installation; leaves more room for your on-going operations

Reliability tested for 500

Hours

Ensures you can count on emergency power when it is needed

Spare Parts 98%

Fulfillment within 24 hours

World's best product support network ensures spare parts are readily available for maintenance and service needs

Generator Set Specifications

Standby Rating 175 ekW
Frequency 60 Hz
Emissions/Fuel Strategy U.S. EPA Tier 3 Certified
Voltage 208 to 600 Volts
Speed 1800 rpm
Duty Cycle Standby

Engine Specifications

Engine Model C7.1 I-6, 4-Cycle Diesel
Bore 4.1in
Stroke 5.31in
Displacement 427.8in³
Compression Ratio 16.7:1
Aspiration Turbocharged, Air to Air Aftercooled
Fuel System Electronic, Common Rail
Governor Type ADEMâ„¢A4

Generator Set Dimensions

Length - Maximum 103.7in
Width - Maximum 51.2in
Height - Maximum 58.7in
Dry Weight - Genset (maximum) 3741lb

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP 1.2 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • UL 2200 Listed
  • ULC Certification Available

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Control Panels
    • GCCP 1.2 Control panel
  • Cooling System
    • Coolant drain line with valves
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Radiator and cooling fan with guards
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Integral / Extended 24 hrs tank
    • Wide skid base
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Termination points for coolant and lube oil drain lines
    • Includes lifting provision and drag points
    • Captive linear vibration isolators between base and engine-generator
  • Starting / Charging System
    • 24V battery with rack and cables
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Telematics
    • Cat® Product Link™ PL444 cellular

Optional Equipment

  • Alternator System
    • Permanent magnet excitation (PMG)
    • Anti-condensation heater
  • Circuit Breakers
    • Single / Multi manual breakers
  • Generator And Generator Attachments
    • Battery disconnect switch
  • Control Panel Options
    • Earth fault (2 wire only)
    • Speed adjust contacts
    • Panel mounted audible alarm
    • Volt free contacts
    • Earth leakage (2 wire only)
    • Control panel heater
    • Speed adjust potentiometer
    • Battery charger
    • Emergency stop with key
  • Control System
    • Static battery charger
    • Volt free contacts for generator set running
  • Cooling System
    • Low coolant temperature
    • Coolant heater
    • Low coolant level shutdown
  • Enclosures
    • Sound attenuated level 2 enclosure
  • Fuel Systems
    • Low fuel level alarm
    • Low fuel level shutdown
    • High fuel level alarm
  • General
    • Stone guards/radiator trans flange
  • Global Certifications
    • Certification for CIS
  • Power Termination
    • Circuit breaker / Aux contacts / Neutral Bars