CG170 Gas Generator Set

CG170 Gas Generator Set

Key Specs

  • Continuous Rating 1560 ekW @1.0pf
  • Fuel Type Natural Gas, Biogas, Coal Gas
  • Maximum Electrical Efficiency 43.30%

Benefits

Up to 47%

Greater oil change interval

Lower lube oil consumption leading to greater time interval between lube oil changes

Up to 14%

savings on service

Extended maintenance intervals leading to lower service costs

Up to 1900 L/Year

Lower lube oil consumption

leading to lower service costs and extended maintenance intervals

Generator Set Specifications

Continuous Rating 1560 ekW @1.0pf
Fuel Type Natural Gas, Biogas, Coal Gas
Maximum Electrical Efficiency 43.30%
Frequency 50 or 60 Hz
RPM 1500 or 1800 rpm

Engine Specifications

Engine Model CG170-16
Displacement 4320in³
Aspiration TA
Bore 6.7in
Stroke 7.7in

Generator Set Dimensions

Length 261.4in
Width 70in
Height 87in
Dry Weight - Genset 32848.5lb

High Efficiency, Lower Operating Costs

  • Miller cycle timing with combustion chamber and spark plug improvement help on saving up to 15% fuel gas per year
  • CG170 (non-miller) is optimized for Island-Mode capability
  • Gearbox helps limit wear and tear on engine components, lowering operating costs and increasing availability

Low installation, Building and Operating Costs

  • Extended maintenance intervals thanks to sooth-free combustion and enlarged oil tank
  • Low fuel consumption due to improved combustion chamber and pre-chamber spark-plugs
  • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)
  • Optimized oil management

Optimized Lubrication Consumption

  • Consumes up to 1900 liter less lube oil per year than comparable models
  • Longer lubricant change and oil change intervals

Standard Equipment

  • Air Inlet
    • Turbocharger with a water-cooled bearing case for all cylinder
    • One-element single-stage air cleaner with enclosure and sevice indicator
  • Control Panels
    • TEM (Total Electronic Management)
  • Cooling
    • Jacket water and SCAC thermostats
    • Electrical jacket water and aftercooler coolant pump
    • flange connections for JW inlet and outlet
    • Cat flanges on SCAC circuit
  • Exhaust
    • PEARL/Low resistence exhaust system
    • Closed crankcase ventilation system
  • Fuel System
    • Independently controlled cylinder monitoring and ignition system
    • Pre-chamber spark plugs
    • Electronic fuel metering valve
  • Generator
    • Busbar connections
    • Anti-condensation space heater
    • closed-coupled generator result in no torque transmission to the base frame
    • Winding temperature detectors
    • Reactive droop
    • 3-phase sensing and KVAR/PF control
    • grid code generator
  • Starting/charging
    • 24V starting motors
    • Battery disconnect switch
  • General
    • Crankshaft vibration damper and guard

Optional Equipment

  • Air Inlet
    • Mounting stand
    • Air cleaner with precleaner
  • Cooling
    • CHP skid
  • Grid Code Compliance
    • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands