CG132B-16

The Cat CG132B family of gas engines are perfectly tailored to the challenges of the power plant in an age of global value chains.Highly efficient with low operating and installation costs and lubricant consumption, the Cat CG132B gas generator set is available with outputs from 400kW to 800kW and comes with the Total Plant and Energy Management (TPEM) system.


SPECIFICATIONS
Gas Generator Sets Specification
Maximum Continuous Rating 800 kW
Fuel Type Natural Gas, Biogas
Maximum Electrical Efficiency 43.5%/42.6%
Maximum Standby Rating 800 kW
Frequency 50/60Hz
RPM 1500/1800rpm


Engine Specifications
Aspiration TA
Bore 5.2 in
Displacement 2135.8 inĀ³
Engine Model CG132
Stroke 6.3 in


Generator Set Dimensions
Length 165 in
Width 70 in
Height 85 in
Dry Weight - Genset NaN lb


BENEFITS & FEATURES
Lower Operating Costs


Optimized engine components mean the CG132 uses up to 50 percent les lubricating oil than competing generator sets, which means more money stays in your company's pockets.

Smaller footprint


The CG132 uses nearly 50 percent less space than similar system. Less space means lower installation costs.

System Control


Control the entire system, not just the engine, with the Cat Total Electronic Management System. Features like temperature and pressure monitoring for each cylinder and anti-knock control allow for maximum power output and the best possible fuel utilization, even if gas composition changes.

Flexible Fuel Usage


Our gas-mixer technology and Total Electronic Management System let you use a wide variety of gases, including problematic gases like digester, landfill and sewage gases




EQUIPMENT
Standard Equipment

Air Inlet
  • One-element single-stage air cleaner with enclosure and sevice indicator
  • Turbocharger with a water-cooled bearing case for all cylinder
Control Panels
  • TPEM (Total Plant & Energy Management System)
Cooling
  • Jacket water and SCAC thermostats
  • Electrical jacket water and aftercooler coolant pump
  • flange connections for JW inlet and outlet
  • ANSI/DN customer flange connections for JW inlet and outlet
  • Flange connections for JW inlet and outlet
  • ANSI/DN customer flange connections for JW inlet and outlet
  • Cat flanges on SCAC circuit
Exhaust
  • Closed crankcase ventilation system
  • PEARL/Low resistence exhaust system
  • Exhaust waste gate for the CG132B-16
  • Electronic fuel metering valve
  • Pre-chamber spark plugs
Fuel system
  • Independently controlled cylinder monitoring and ignition system
  • Electronic fuel metering valve
  • Pre-chamber spark plugs
  • Independently controlled cylinder monitoring and ignition system
Generator
  • Reactive droop
  • Bus bar connections
  • Winding temperature detectors
  • Anti-condensation space heater
  • Reactive droop
  • 3-phase sensing and KVAR/PF control
  • Bus bar connections
  • Winding temperature detectors
  • closed-coupled generator result in no torque transmission to the base frame
  • Anti-condensation space heater
  • grid code generator
  • 3-phase sensing and KVAR/PF control
General
  • Crankshaft vibration damper and guard
Starting/Charging
  • 24V starting motors
  • Battery disconnect switch
  • Crankshaft vibration damper and guard
  • Battery disconnect switch

Optional Equipment

Air Inlet
  • Mounting stand
  • Air cleaner with precleaner
Cooling
  • CHP skid
  • CHP skid

CALL NOW TO LEARN MORE

Andy Downs
423-463-2131 or 423-698-6943

Neal Reinhardt
865-595-1034 or 865-771-1036


HOW CAN WE HELP?
SHARE YOUR FEEDBACK OR ASK A QUESTION
Feel free to ask a question or share a comment about the information on this page.

To help us answer your question or respond to your comment, please enter your email address.