C13 (50 HZ)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.


SPECIFICATIONS
Generator Set Specifications
Minimum Rating 350 kVA
Maximum Rating 450 kVA


Generator Set Configurations
Emissions/Fuel Strategy Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards


Generator Set Specifications
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm


Engine Specifications
Engine Model C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Displacement 762.8 in³
Fuel System MEUI
Aspiration Air to Air Aftercooled
Governor Type Adem™A4
Compression Ratio 16.3:1
Bore 5.12 in
Stroke 6.18 in


Generator Set Dimensions
Length - Maximum 186.7 in
Width - Maximum 79.3 in
Height - Maximum 84 in


BENEFITS & FEATURES
Design Criteria


The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response.

Cat Diesel Engine


  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Generator


  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency

Cat EMCP Control Panel


The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP 4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP 4 systems can be further customized to meet your needs through programming and expansion modules.

World Wide Product Support


Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

EQUIPMENT
Standard Equipment

Air Inlet System
  • Air cleaner; light duty with disposable paper filter
  • Aftercooler core
  • Turbocharger
Control Panel
  • EMCP 4.2
Cooling System
  • Radiator and cooling fan with guard
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Caterpillar Extended Life Coolant
Exhaust System
  • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
Fuel System
  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank
Generator and Attachments
  • A frame generator - IP21 Protection
  • Optional LC frame generator - IP23 Protection
  • Integrated Voltage Regulator
  • Power center, IP22
  • Segregated low voltage (AC/DC) wiring panel
  • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre
Governing System
  • Cat Electronic Governor (ADEM A4)
Lube System
  • Oil Cooler
  • Lubricating oil
  • Oil drain valves
Mounting System
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant and lube oil drain lines
Starting / Charging System
  • 24V battery with rack and cables
General
  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

European Certificates
  • EU certificate of conformance
  • Global certificate for CIS
Air Inlet System
  • Single element air cleaner
  • Dual element air cleaner
Circuit Breakers
  • 3 Pole (IEC-100% rated) circuit breaker
  • 4 Pole (IEC-100% rated) circuit breaker
  • 3 Pole (IEC-100% rated) circuit breaker - Motorised
  • 4 Pole (IEC-100% rated) circuit breaker - Motorised
  • Circuit breaker (IEC) auxiliary contacts
  • Shunt trip for IEC circuit breaker
  • Pad-lockable circuit breaker device
  • Power terminal strip
Control Panels
  • Volt free contacts
  • EMCP 4.3, EMCP 4.4
  • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
  • Local alarm modules: Local annunciator
  • Remote annunciator modules
Cooling System
  • Radiator duct flange
  • Stone guards
  • Low coolant temperature alarm
Enclosures
  • Sound attenuated enclosures
  • High ambient sound attenuated enclosures
Exhaust System
  • Mufflers - End in / End out
  • 10, 25 and 35 dBA attenuation
  • 6 and 8 inch flange GP
  • Flexible 8 inch exhaust fittings
  • 6 and 8 inch elbow kit
Fuel System
  • Integral dual wall fuel tank base
  • Manual fuel transfer pump
  • Fuel transfer system controls
Generator and Attachments
  • Ingress protection
  • Permanent magnet generator
  • Space heaters
  • A frame oversize generator
  • A frame CIP generator
  • LC frame generator
  • LC CIP generator
Lube System
  • Manual sump pump
Mounting System
  • Narrow skid base
starting / Charging System
  • 5 Amp single battery charger
  • Battery disconnect switch
  • Jacket water heater