3516E (50 HZ)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.


SPECIFICATIONS
Generator Set Specifications
Minimum Rating 2750 kVA
Maximum Rating 3000 kVA (3100 kVA without fan)
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 380 to 11000 volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Mission Critical, Prime


Engine Specifications
Engine Model 3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel
Bore 6.69 in
Stroke 8.46 in
Displacement 4766 in
Compression Ratio 14:01
Aspiration TA
Fuel System Electronic unit injection
Governor Type Adem™5


Generator Set Dimensions
Length - Maximum 296.8 in
Width - Maximum 87.2 in
Height - Maximum 133.5 in
Dry Weight - Genset (maximum) 43541 lb


BENEFITS & FEATURES
Cat Generator Set Package


  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets other NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine


  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Alternator


    SR5
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP 4 Control Panel


  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System


  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications


  • IBC Seismic Certification
  • EU Certification of Conformance (CE)
  • EEC Declaration of Conformity

One Safe Source


  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

World Wide Product Support


  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

EQUIPMENT
Standard Equipment

Air Inlet System
  • Air cleaner
  • Single element canister type with service indicator
Control Panel
  • EMCP 4.2
  • Emergency stop pushbutton
  • Panel lights
  • EMCP4.2 controller includes:
  • 24-volt DC operation
  • Environmental sealed front face
  • Text alarm / event descriptions
  • Generator mounted - rear facing
  • Controls:
  • Speed adjust
  • Engine cool-down timer
  • Engine cycle crank
  • Alarm acknowledge
  • Lamp test
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • RPM
  • DC volts
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Volts (L-L & L-N)
  • Frequency (Hz)
  • Amps (per phase & average)
  • Power Factor (per phase & average)
  • kW (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • kW-hr (total)
  • kVAr-hr (total)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Emergency stop
  • Failure to start (overcrank)
  • Low coolant temperature
  • Low coolant level
  • Programmable protective relaying functions:
  • Generator phase sequence
  • Over / under voltage (27/59)
  • Over / under frequency (81 o/u)
  • Reverse power (kW) (32)
  • Reverse reactive power (kVAr) (32RV)
  • Overcurrent (50/51)
  • Communications:
  • Customer data link (Modbus RTU)
  • Accessory module data link
  • Serial annunciator module data link
  • 6 programmable digital inputs
  • 4 programmable relay outputs (Form A)
  • 2 programmable relay outputs (Form C)
  • 2 programmable digital outputs
Cooling System
  • JWAC
  • Radiator fan and fan drive
  • Fan and belt guards
  • Coolant drain line with valve
  • Coolant level sensors
  • Caterpillar Extended Life Coolant
Exhaust System
  • Dry exhaust manifold
  • Flanged faced outlet(s)
Fuel System
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump
Generators and Attachments
  • 3 phase brushless, salient pole
  • 6 lead
  • Generator set packages include Caterpillar's Digital Voltage Regulator (CDVR). CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
  • Random wound
  • Internal excitation
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby).
  • Winding temperature detectors
  • Bus bar connections, top center mounted, top cable entry
  • IEC standard hole pattern
Governing System
  • ADEM III
Literature
  • English
Lube System
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cooler
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal
Mounting System
  • Rails - engine / generator / radiator mounting
  • Rubber anti-vibration mounts (shipped loose)
Starting / Charging System
  • 24 Volt electric starting motor
  • Battery and battery rack w/cables
  • Battery disconnect switch
General
  • Paint: Caterpillar yellow with high gloss black rails & radiator
  • Right hand servicing
  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation

Optional Equipment

Air Inlet System
  • Dual element air cleaners
  • Heavy duty air cleaners
  • Remote air inlet adapters
  • Air inlet protection
Circuit Breakers
  • Optional busbar power connections
  • Load take off; IEC standard hole
  • Center posts busbars
  • Cable entry options
  • Control packaging for enclosures
  • Trip Units
  • EMAX breakers
Power Termination
  • Circuit breakers, IEC compliant
Control Panels
  • EMCP 4.3, EMCP 4.4
  • Language options
  • Busbar connections
  • EMAX breaker connections
  • Annunciator modules
  • Governors
  • External box clips
  • Auxiliary box
  • Customer interface options
  • Generator temperature monitoring
  • Voltage raise / lower switch
  • Remote speed adjust
  • Vandal proof panel door
  • Local and remote monitoring
Cooling System
  • Optional Serpentine radiators
  • Water level switch gauges
  • Heat exchangers
  • Radiator duct flanges
European Certifications
  • EU declaration of conformity
Exhaust System
  • Mufflers
  • Muffler mounting kits
  • Flexible fittings
  • Through wall installation kit
Fuel System
  • Primary fuel filter
  • Fuel coolers
Generators and attachments
  • Optional generators
  • 3 Phase, Random wound, Internal excitation
  • Number of leads: 6
  • 3 Phase, 380 / 400 / 415 / 3300 / 6600 / 10000 / 10500 / 11000 volt
     
  • Random wound
  • Internal excitation
  • Pitch: 0.6667
Instrumentation
  • Pyrometers and thermocouples
Lube System
  • Oil level regulator
  • Electric prelube pumps
  • Manual prelube sump pumps
Mounting System
  • Spring type vibration isolators
  • IBC vibration isolators
Protection System
  • Explosion relief valves
Special Tests / Reports
  • CSA test and certification
  • Neutral ground certificate
  • IBC seismic certificate
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
Starting / Charging System
  • Charging alternators - 50 Amp
  • 10 and 20 amp battery chargers
  • 24 Volt battery sets - Dry
  • Dual 24 volt electric starting motors
  • ETHER starting aids
  • Jacket water heaters
General
  • Engine barring group

CALL NOW TO LEARN MORE

Andy Downs
423-463-2131 or 423-698-6943

Neal Reinhardt
865-595-1034 or 865-771-1036