3516E (50 HZ)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.


SPECIFICATIONS
Generator Set Specifications
Height - Maximum 92.2 in
Length - Maximum 218.3 in
Width - Maximum 72 in
Minimum Rating 2750 kVA
Maximum Rating 3000 kVA (3100 kVA without fan)
Voltage 380 to 11,000 volts
Frequency 50 Hz
Speed 1500 RPM


Generator Set Configurations
Emissions/Fuel Strategy Low Fuel Consumption


Engine Specifications
Engine Model 3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel
Compression Ratio 14:01
Aspiration TA
Governor Type Adem™5
Fuel System Electronic unit injection
Bore 6.69 in
Stroke - HD 8.46 in


BENEFITS & FEATURES
Cat Diesel Engine


  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Generator


  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency

Cat EMCP Control Panel


The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

Seismic Certification


  • Seismic Certification available.
  • Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength.
  • IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer
  • Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007, CBC 2010

Design Criteria


The generator set accepts 100% rated load in one step per NFPA 110 and conforms to the ISO 8528-5:2013 G3 for load acceptance & steady state.

Single-Source Supplier


Fully prototype tested with certified torsional vibration analysis available

World Wide Product Support


Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat® SOSSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products.

EQUIPMENT
Standard Equipment

Air Inlet System
  • Air cleaner
  • Single element canister type with service indicator
Control Panel
  • EMCP 4.2
  • Emergency stop pushbutton
  • Panel lights
  • EMCP4.2 controller includes:
  • 24-volt DC operation
  • Environmental sealed front face
  • Text alarm / event descriptions
  • Generator mounted - rear facing
  • Controls:
  • Speed adjust
  • Engine cool-down timer
  • Engine cycle crank
  • Alarm acknowledge
  • Lamp test
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • RPM
  • DC volts
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Volts (L-L & L-N)
  • Frequency (Hz)
  • Amps (per phase & average)
  • Power Factor (per phase & average)
  • kW (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • kW-hr (total)
  • kVAr-hr (total)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Emergency stop
  • Failure to start (overcrank)
  • Low coolant temperature
  • Low coolant level
  • Programmable protective relaying functions:
  • Generator phase sequence
  • Over / under voltage (27/59)
  • Over / under frequency (81 o/u)
  • Reverse power (kW) (32)
  • Reverse reactive power (kVAr) (32RV)
  • Overcurrent (50/51)
  • Communications:
  • Customer data link (Modbus RTU)
  • Accessory module data link
  • Serial annunciator module data link
  • 6 programmable digital inputs
  • 4 programmable relay outputs (Form A)
  • 2 programmable relay outputs (Form C)
  • 2 programmable digital outputs
Cooling System
  • JWAC
  • Radiator fan and fan drive
  • Fan and belt guards
  • Coolant drain line with valve
  • Coolant level sensors
  • Caterpillar Extended Life Coolant
Exhaust System
  • Dry exhaust manifold
  • Flanged faced outlet(s)
Fuel System
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump
Generators and Attachments
  • 3 phase brushless, salient pole
  • 6 lead
  • Generator set packages include Caterpillar's Digital Voltage Regulator (CDVR). CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
  • Random wound
  • Internal excitation
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby).
  • Winding temperature detectors
  • Bus bar connections, top center mounted, top cable entry
  • IEC standard hole pattern
Governing System
  • ADEM III
Literature
  • English
Lube System
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cooler
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal
Mounting System
  • Rails - engine / generator / radiator mounting
  • Rubber anti-vibration mounts (shipped loose)
Starting / Charging System
  • 24 Volt electric starting motor
  • Battery and battery rack w/cables
  • Battery disconnect switch
General
  • Paint: Caterpillar yellow with high gloss black rails & radiator
  • Right hand servicing
  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation

Optional Equipment

Air Inlet System
  • Dual element air cleaners
  • Heavy duty air cleaners
  • Remote air inlet adapters
  • Air inlet protection
Power Termination
  • Circuit breakers, IEC compliant
Circuit Breakers
  • Optional busbar power connections
  • Load take off; IEC standard hole
  • Center posts busbars
  • Cable entry options
  • Control packaging for enclosures
  • Trip Units
  • EMAX breakers
Control Panels
  • EMCP 4.3, EMCP 4.4
  • Language options
  • Busbar connections
  • EMAX breaker connections
  • Annunciator modules
  • Governors
  • External box clips
  • Auxiliary box
  • Customer interface options
  • Generator temperature monitoring
  • Voltage raise / lower switch
  • Remote speed adjust
  • Vandal proof panel door
  • Local and remote monitoring
Cooling System
  • Optional Serpentine radiators
  • Water level switch gauges
  • Heat exchangers
  • Radiator duct flanges
European Certifications
  • EU declaration of conformity
Exhaust System
  • Mufflers
  • Muffler mounting kits
  • Flexible fittings
  • Through wall installation kit
Fuel System
  • Primary fuel filter
  • Fuel coolers
Generators and attachments
  • Optional generators
  • 3 Phase, Random wound, Internal excitation
  • Number of leads: 6
  • 3 Phase, 380 / 400 / 415 / 3300 / 6600 / 10000 / 10500 / 11000 volt
     
  • Random wound
  • Internal excitation
  • Pitch: 0.6667
Instrumentation
  • Pyrometers and thermocouples
Lube System
  • Oil level reg-1 shallow pan
  • Electric prelube pumps
  • Manual prelube sump pumps
Mounting System
  • Spring type vibration isolators
  • IBC vibration isolators
Protection System
  • Explosion relief valves
Special Tests / Reports
  • CSA test and certification
  • Neutral ground certificate
  • IBC seismic certificate
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
Starting / Charging System
  • Charging alternators - 50 Amp
  • 10 and 20 amp battery chargers
  • 24 Volt battery sets - Dry
  • Dual 24 volt electric starting motors
  • ETHER starting aids
  • Jacket water heaters
General
  • Engine barring group

CALL NOW TO LEARN MORE

Andy Downs
423-463-2131 or 423-698-6943

Neal Reinhardt
865-595-1034 or 865-771-1036


HOW CAN WE HELP?
SHARE YOUR FEEDBACK OR ASK A QUESTION
Feel free to ask a question or share a comment about the information on this page.

To help us answer your question or respond to your comment, please enter your email address.