3516B DGB™ (60 HZ)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.


SPECIFICATIONS
Generator Set Specifications
Minimum Rating 1640 ekW
Maximum Rating 1825 ekW
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 380 to 13800 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Prime, Continuous


Engine Specifications
Engine Model 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore 6.69 in
Stroke 8.46 in
Displacement 4764.73 in
Compression Ratio 15.5:1
Aspiration TA
Fuel System Electronic unit injection
Governor Type Adem™4


Generator Set Dimensions
Length - Maximum 274.2 in
Width - Maximum 90 in
Height - Maximum 92.9 in
Dry Weight - Genset (maximum) 33300 lb


BENEFITS & FEATURES
Cat Generator Set Package


  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets other NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine


  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Alternator


    SR5
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP 4 Control Panel


  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System


  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications


  • UL2200
  • CSA
  • IBC Seismic Certification

One Safe Source


  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

World Wide Product Support


  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

EQUIPMENT
Standard Equipment

Air Inlet System
  • Air cleaner, single element canister type
Control System
  • EMCP 4.2
  • Emergency stop pushbutton
  • 24 Volt DC operation
  • Environmental sealed front face
  • Text alarm / event descriptions
  • Generator mounted - rear facing
  • Generator set packages include Caterpillars Voltage
  • Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
  • Limiter and exciter diode monitor
  • Controls:
  • Speed adjust
  • Auto/start/stop control
  • Engine cool-down timer
  • Engine cycle crank
  • Alarm acknowledge
  • Lamp test
  • Load histogram feature
  • PLC functionality
  • Customizable screens
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • RPM
  • DC volts
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Volts (L-L & L-N), frequency (Hz)
  • Amps (per phase & average)
  • Power Factor (per phase & average)
  • kW (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • kW-hr (total)
  • kVAr-hr (total)
  • Warning / shutdown with common LED indication of shutdowns for:
  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Emergency stop
  • Failure to start (overcrank)
  • Low coolant temperature
  • Low coolant level
  • Programmable protective relaying functions:
  • Generator phase sequence
  • Over/Under voltage (27/59)
  • Over/Under Frequency (81 o/u)
  • Reverse Power (kW) (32)
  • Reverse Reactive Power (kVAr) (32RV)
  • Overcurrent (50/51)
  • Communications:
  • Customer data link (Modbus RTU)
  • Accessory module data link
  • Serial annunciator module data link
  • Cat Connect
  • 3 Analog inputs
  • 6 Customer programmable digital inputs
  • Number of I/O varies on options selected:
  • 4 Programmable relay outputs (Form A)
  • 1 Programmable relay outputs (Form C)
  • 1 Programmable digital outputs
Cooling System
  • Package mounted radiator
Exhaust System
  • Dry exhaust manifold
  • Flanged faced outlet(s)
Fuel System
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump
General
  • Paint - Caterpillar yellow except rails and radiators gloss black
  • RH Service
  • Flywheel and Flywheel housing-SAE No. 00
  • SAE Standard Rotation
Generators and Attachments
  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection
  • 3 Phase brushless, salient pole
  • 6 lead
  • LV
  • Random wound
  • Permanent magnet
  • Winding temperature detectors
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
  • MV:
  • Form wound
  • Permanent magnet
  • Winding temperature detectors
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Bus bar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
  • HV:
  • Form wound
  • Permanent magnet
  • Winding temperature detectors
  • Anti condensation space heater
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
Governing System
  • ADEM A3
Lube System
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cooler
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal
Mounting System
  • Rails - engine/generator/radiator mounting.
  • Anti-vibration mounts (shipped loose).
  • Rubber anti-vibration mounts (shipped loose)
Starting System
  • 24 Volt electric starting motor
  • 45 Amp charging alternator
  • Battery and battery rack w/cables
  • Battery disconnect switch

Optional Equipment

Air Inlet System
  • Single Element Filter
  • Dual Element Air Cleaner
  • Optional Radiator Arrangements
  • Standard ambient radiators
  • Standard ambient ATAAC radiators
Control Panels
  • EMCP 4.3, EMCP 4.4
  • Generator main terminal box
  • Load share module
  • Digital I/O module
  • Remote monitoring software
  • Empty upper box
  • Side extension box
  • Cable Shroud
  • Annunciator - local
  • Annunciator - remote
  • Vandal proof panel cover
Cooling System
  • Water level switch gauges
  • Coolant
Crankcase Systems
  • Crankcase protection groups:
  • No explosion relief valves
  • Explosion relief valve
  • Crankcase ventilation systems
Exhaust System
  • Elbows>
  • Flange and exhaust expanders
  • Flanges
  • Flexible fittings
  • Y Adapters
  • Mufflers
  • Exhaust offset
  • Tier 4 lean emissions moduel
  • Tier 4 dosing cabinet
  • Tier 4 clean emission MOD kits
  • Elean emission parts
Extended Service Coverage
  • Platinum, Silver and Gold coverage
Fuel System
  • Primary fuel filter
  • Gas fuel filter
  • Fuel priming pump (Tier 4)
Generators and Attachments
  • 1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, IE, No. of leads = 6, Pitch = .6667
  • 1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, PM, No. of leads = 6, Pitch = .6667
  • 1600 Frame - 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM ,FW, PM, No. of leads = 6, Pitch = .6667
  • 1800 Frame
  • Generators high voltage
  • 2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
  • 3000 Frame - 12470, 13200, 13800 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
  • Space heater kit
  • Generator conversions
  • Hi volt optional attachments
  • Alternator air cleaner
  • Differential current transformers
Instrumentation
  • Pyrometer and Termocouples
Lube System
  • Lube oil in standard sump
  • Oil level regulator
  • Prelube pump groups
Mounting System
  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • IBC vibration isolators
Power Connections
  • Grounding groups
  • Neutral ground connections
  • Center post busbar
  • Right side power connections
  • Cable entry - right side
  • left side power connections
  • Cable entry - left side
  • Rear power connections
  • Cable entry - rear
Power Termination
  • Circuit breakers - LV Packages
  • 1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated circuit breakers
  • 2000, 2500, 3200 Amp, 4 Pole, IEC rated circuit breakers
  • 2000, 2500, 3200 Amp, 3 Pole, IEC rated circuit breakers
Special Tests / Reports
  • Seismic certifications
  • OSPD certification
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
  • Standard engine test
  • Generator set report
  • Fuel consumption test
  • Torsional vibration analysis
Starting / Charging
  • Engine barring devices
  • Batteries, racks and cables
  • 10, 20 and 35 Amp battery charger
  • 50 Amp NFPA battery charger
  • Electric starting motors
  • Air starting motors
  • Starter covers
  • Air pressure regulator
  • Jacket water heaters

CALL NOW TO LEARN MORE

Andy Downs
423-463-2131 or 423-698-6943

Neal Reinhardt
865-595-1034 or 865-771-1036