3512 (60 HZ)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.


SPECIFICATIONS
Generator Set Specifications
Minimum Rating 890 ekW
Maximum Rating 1250 ekW
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 380 to 13800 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous


Engine Specifications
Engine Model 3512 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore 6.69 in
Stroke 7.48 in
Displacement 3161.03 in³
Compression Ratio 13.5:1
Aspiration TA
Fuel System Direct Unit Injection
Governor Type Woodward


Generator Set Dimensions
Length - Minimum 214.8 in
Length - Maximum 218.8 in
Width - Maximum 77.8 in
Height - Maximum 93.2 in
Dry Weight - Genset (minimum) 22210 lb
Dry Weight - Genset (maximum) 22650 lb


BENEFITS & FEATURES
Cat Diesel Engine


  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Generator


  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency

Cat EMCP Control Panel


The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

Seismic Certification


  • Seismic Certification available.
  • Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength.
  • IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer
  • Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007, CBC 2010
  • Pre-approved by OSHPD and carries an OSP-0321-10 for use in healthcare projects in California

Design Criteria


The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response.

UL 2200 / CSA - Optional


  • UL 2200 listed packages
  • CSA Certified
  • Certain restrictions may apply.
  • Consult with your Cat® Dealer.

Single-Source Supplier


Fully prototype tested with certified torsional vibration analysis available

World Wide Product Support


Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat® SOSSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products.

EQUIPMENT
Standard Equipment

Air Inlet System
  • Air cleaner; single element canister type with service indicator
Control Panel
  • EMCP 4.2
  • Features include:
  • Emergency stop pushbutton
  • 24-volt DC operation
  • Environmental sealed front face
  • Text alarm / event descriptions
  • Generator mounted - rear facing
  • Controls:
  • Auto/start/stop control
  • Engine cool-down timer
  • Engine cycle crank
  • Alarm acknowledge
  • Lamp test
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • RPM
  • DC volts
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Volts (L-L & L-N), frequency (Hz)
  • Amps (per phase & average)
  • Power factor (per phase & average)
  • kW (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • kW-hr (total)
  • kVAr-hr (total)
  • Warning / shutdown with common LED indication of shutdowns for:
  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Emergency stop
  • Failure to start (overcrank)
  • Low coolant temperature
  • Low coolant level
  • Programmable protective relaying functions:
  • Generator phase sequence
  • Over / under voltage (27 / 59)
  • Over / under frequency (81 o / u)
  • Reverse Power (kW) (32)
  • Reverse Reactive Power (kVAr) (32RV)
  • Overcurrent (50 / 51)
  • Communications:
  • Customer data link (Modbus RTU)
  • Accessory module data link
  • Serial annunciator module data link
  • 6 programmable digital inputs
  • 4 programmable relay outputs (Form A)
  • 2 programmable relay outputs (Form C)
  • 2 programmable digital outputs
Cooling System
  • JWAC
  • Radiator fan and fan drive
  • Fan and belt guards
  • Coolant drain line with valve
  • Coolant level sensors
  • Caterpillar Extended Life Coolant
Exhaust System
  • Dry Exhaust Manifold.
  • Exhaust flange outlet(s)
Fuel System
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump
Generators and Attachments
  • 3 phase brushless, salient pole
  • 6 lead
  • Generator set packages include Caterpillar's Digital Voltage Regulator (CDVR)
  • CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
  • LV:
  • Random wound
  • Internal Excitation
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Winding temperature detectors
  • Busbar connections, top center mounted, top cable entry. 50 Hz models: IEC standard hole pattern
  • 1800 frames are form wound, permanent magnet, with winding temperature detectors
Governing System
  • Woodward 2301A isochronous governor
Lube System
  • Lubricating oil.
  • Gear type lube oil pump.
  • Integral lube oil cooler
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal
Mounting System
  • Rails - engine/generator/radiator mounting
  • Rubber anti-vibration mounts (shipped loos
Starting / Charging System
  • 24-volt electric starting motor
  • Battery and battery rack w/cables
  • Battery disconnect switch
General
  • Caterpillar Yellow with high gloss black rails & radiator
  • Right hand servicing
  • Flywheel and Flywheel housing-SAE No. 00
  • SAE Standard Rotation

Optional Equipment

Air Inlet System
  • Air cleaner - Dual element
  • Remote air inlet adapters
  • Air inlet protection
Circuit Breakers
  • Optional busbar power connections
  • Breaker harnesses
  • Low voltage, IEC standard hole
  • Cable entry options
  • Enclosures - control packaging
  • EMAX breakers
  • Busbar connections
  • EMAX breaker connections
Control Panels
  • EMCP 4.3, EMCP 4.4
  • Annunciator modules
  • Governors
  • Mounting group - External box clips
  • Auxiliary box
  • Customer interface options
  • Generator temperature monitoring
Cooling System
  • 3512 MUI 1500 Radiators PGS
  • Water level switch gauges
  • Heat exchangers
Certificates
  • European union certification
  • EU declaration of conformity
  • Eurasian conformity (EAC) mark
  • European directive genset DOI
Exhaust System
  • Mufflers
  • Flexible fittings
  • Through wall installation kit
Fuel System
  • Primary fuel filter
Generators and Attachments
  • Generator conversions - IE and PM
  • Space heater kt
Instrumentation
  • Pyrometers
Lube System
  • Oil level reg-1 shallow pan
  • Electric prelube pumps
  • Manual prelube sump pumps
Mounting System
  • Vibration Isolator options
Protection System
  • Explosion relief valves
Special Tests / Reports
  • Neutral grounding connection
  • Neutral ground - LV
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
  • IBC seismic certification
Starting / Charging System
  • Charging alternators
  • Battery chargers (10 and 20 amp)
  • Battery sets - 24 Volt, dry
  • Electric starting motors - Duel 24 Volt
  • Starting aids
  • Jacket water heaters
General
  • Engine barring group - installed

CALL NOW TO LEARN MORE

Andy Downs
423-463-2131 or 423-698-6943

Neal Reinhardt
865-595-1034 or 865-771-1036